VENTILATION
Ventilation is a must in any treatment of shipboard fire fighting because the thinking has changed since World War II. Even though industrial fire fighting ashore has taken this into account, practices in fire fighting aboard ship have lagged behind. In the initial stage of shipboard fire fighting, the compartment is closed tightly and the ventilation shut down. The thinking behind this is that the fire may die out from oxygen starvation.
The problem with buttoning up and shutting down ventilation is that the fire continues to run its course within the compartment. The fire progresses from the first or beginning stage on through the third or smoldering stage with heavy production of unburned gases. Conditions become critical as the third stage of burning is entered into since temperatures within the compartment are superheated and above what a human can withstand. Worse is that in the third stage of burning, unburned products of combustion are being formed and deposited throughout the room. Heat within the compartment is being carried away into compartments with the result that eventually flammables in those compartments may reach their ignition temperature. In this stage of the fire the real problem develops when fresh air enters the room when a door is opened for attack on the fire. As the fresh cool air enters, the oxygen in this parcel of air immediately is involved in rapid combustion with the unburned gases that are spread throughout the compartment. Instantaneous combustion occurs with results that look similar to an explosion. Also, the cool air that enters the compartment will be heated and expand to ten times its original volume when it comes into contact with the superheated gases. Since the compartment is sealed up except for the open door, the gases find that they have only one way out in order to relieve the pressure buildup in the compartment and that is out the open door. It is possible that the ball of flame and superheated gases that force their way out the open door will burn all personnel within the adjacent compartment. In any case no fire fighter will be able to enter the compartment once the thermal boundary has been severely disrupted.
Since air is going to enter the compartment anyway when the entry door is opened and since the fire fighters are going to find that they are not going to be able to enter the compartment due to existing conditions, it would be wise to establish controlled conditions in the compartment that will lower temperatures, vent unburned gases and superheated gases to the weather deck, and improve visibility within the compartment. Modern shipboard construction practice involves the use of mechanical supply ventilation as well as mechanical exhaust ventilation. In the initial stages of the fire the supply ventilation only is shut off to the compartment on fire to eliminate a source of fresh oxygen to the seat of the fire. Rather than shutting of the exhaust ventilation as has been traditional practice, the exhaust ventilation is kept running at full speed. Rather than hot gases collecting within the room, they are pulled off as fast as they are generated in the overhead. No thermal boundary is allowed to develop within the room; no unburned gases of combustion are allowed to collect; no gas pressure buildup is allowed to develop.
When the fire fighters open the access door to this compartment a draft will be exhausted through the door and into the compartment to the exhaust ventilation system. The fire fighters have hose in hand, and are ready to extinguish the fire on entry so any fanning of the fire due to the door opening and the draft will be only temporary in nature. Since temperatures are down and unburned gases at a minimum in the compartment the chance of explosive combustion due to the draft is at a minimum. Visibility is improved in the compartment due to this procedure since smoke is being pulled out of the compartment.
The key to shipboard fire fighting is to have drills and a plan for all ship areas so you are always ready in case a fire does break out.
Showing posts with label DAMAGE CONTROL. Show all posts
Showing posts with label DAMAGE CONTROL. Show all posts
Saturday, December 1, 2007
FIRE FIGHTING ABOARD SHIP #6 (OVERHAUL)
THE OVERHAUL
Once the fire is out the overhaul of the fire area begins. I've listed the steps below;
1. Reestablish ventilation in the compartment to remove smoke and hot gases. Rig portable ventilation if necessary.
2. Use fire axes and picks to probe for smoldering embers. Use water as embers are uncovered.
3. Rig portable water pumps if this has not already been done during the fire-fighting process. Remove excess water.
4. Remove all items from the room involved in the fire and take these items to the weather deck.
5. Use a fire axe to make entry into false overheads, bulkheads, and decks to make sure that the fire is not continuing in these spaces. Smoldering and cable fires may continue undetected ifthis is not accomplished. Sweep up and remove all ash and debris from the compartment.
THE FLASHBACK WATCH
The final step prior to leaving the fire area is to set the flashback watch. The watch must be equipped with a charged fire hose and a fire axe. The purpose of this watch is to continue to wet down the smoldering material and probe for hidden fire.
Once the fire is out the overhaul of the fire area begins. I've listed the steps below;
1. Reestablish ventilation in the compartment to remove smoke and hot gases. Rig portable ventilation if necessary.
2. Use fire axes and picks to probe for smoldering embers. Use water as embers are uncovered.
3. Rig portable water pumps if this has not already been done during the fire-fighting process. Remove excess water.
4. Remove all items from the room involved in the fire and take these items to the weather deck.
5. Use a fire axe to make entry into false overheads, bulkheads, and decks to make sure that the fire is not continuing in these spaces. Smoldering and cable fires may continue undetected ifthis is not accomplished. Sweep up and remove all ash and debris from the compartment.
THE FLASHBACK WATCH
The final step prior to leaving the fire area is to set the flashback watch. The watch must be equipped with a charged fire hose and a fire axe. The purpose of this watch is to continue to wet down the smoldering material and probe for hidden fire.
Labels:
DAMAGE CONTROL
Friday, November 30, 2007
FIRE FIGHTING ABOARD SHIP #5 (ATTACK)
Direct Attack without Entry. Open the door slightly and direct a solid stream of water at the seat of the class A fire. Keep in mind that a solid stream of water can be projected approximately 75 feet when 100 psi is available at the fire main. This method of extinguishment may be desirable when the compartment has become superheated and entry by the fire fighters would result in too much body punishment to the fire fighters.
Indirect Attack (for Smaller Compartments). Fire extinguishment can be effected by briefly opening the door to the compartment that is on fire and then directing high-velocity fog into the overhead of the compartment. The superheated gases in the overhead will flash this water to steam and the steam will begin to fill the compartment. When sufficient steam has been generated in the compartment, close the door tightly and allow the steam to smother the fire. This method is useful for small compartments where the fire has progressed to the second or the third stage and the gases in the overhead have become superheated.
Direct Attack Using Proper Technique. Fire fighters enter the compartment and stay low to the deck. The 4-foot applicator is used for heat shielding and personnel cooling. As little water as possible is used from the attack nozzle so as not to stir up the thermal boundary in the overhead. The source of the fire is approached as closely as possible without using water. Solid stream is used directly on the seat of the class A fire.
Direct Attack Using Improper Technique. The result of this is that the water reaching the superheated gases in the overhead flashes to steam. The turbulence of the high velocity fog causes the thermal boundary to become disturbed. The superheated gases and steam are forced down to the deck from the overhead with the result that the fire fighter will be forced out of the compartment by overheating.
Indirect Attack (for Smaller Compartments). Fire extinguishment can be effected by briefly opening the door to the compartment that is on fire and then directing high-velocity fog into the overhead of the compartment. The superheated gases in the overhead will flash this water to steam and the steam will begin to fill the compartment. When sufficient steam has been generated in the compartment, close the door tightly and allow the steam to smother the fire. This method is useful for small compartments where the fire has progressed to the second or the third stage and the gases in the overhead have become superheated.
Direct Attack Using Proper Technique. Fire fighters enter the compartment and stay low to the deck. The 4-foot applicator is used for heat shielding and personnel cooling. As little water as possible is used from the attack nozzle so as not to stir up the thermal boundary in the overhead. The source of the fire is approached as closely as possible without using water. Solid stream is used directly on the seat of the class A fire.
Direct Attack Using Improper Technique. The result of this is that the water reaching the superheated gases in the overhead flashes to steam. The turbulence of the high velocity fog causes the thermal boundary to become disturbed. The superheated gases and steam are forced down to the deck from the overhead with the result that the fire fighter will be forced out of the compartment by overheating.
Labels:
DAMAGE CONTROL
FIRE FIGHTING ABOARD SHIP #4 (FIGHTING FIRE)
FIGHTING THE FIRE
Once you arrive on scene to fight the fire you should cool down the door entrance to the compartment or zone on fire. Once the entrance is cool, a backup man can step forward and, while standing outside the swing of the door, crack open the door and slip the 4-foot applicator into the opened door to continue cooling the back side of the door, It is important to stand outside the swing of the door due to the possibility of the door being blown open when fresh air enters into the compartment through the crack in the door.
Open the door fully while using a vertical sweeping motion with the attack nozzle on high velocity fog. This water action will keep the smoke and fire gases inside the compartment.
At this point the emergency squad officer can make a determination as to what type of attack should be made. If the compartment is small then an indirect attack can be mounted from the compartment entrance. Types of indirect attack are as follows:
1. Point attack nozzle into overhead and alternate between solid stream and high velocity fog for about 30 seconds; then close the compartment door. The water flashes to steam and smothers the compartment.
2. If the seat of the fire can be seen from the door, the nozzle man can use solid stream to hit the fire from the door without ever entering the compartment. This has the advantage of keeping the fire fighters out of the hot gases and smoke in the compartment.
If the compartment is very large then a direct attack must be mounted; the procedure is for the hose men to enter the compartment while staying low to the deck. Do not spray water into the overhead or attempt to cool down bulkheads while making the approach to the seat of the fire. To do this will cause steam to be generated and cause the thermal boundary to be brought to the deck level, making it impossible for the fire fighters to stay in the compartment. It might be best to keep the attack nozzle shut off during the approach if this is possible. Use only the backup nozzle and applicator for a heat shield and cooling. Once within range of the seat of the fire, apply water vigorously at the seat of the fire until the fire is extinguished. Use only the amount of water necessary to do the job. Remember, you are fighting a fire in a ship and any water you put into the ship must be taken out.
At this point the officer in charge should arrange for bilge suction to be started on the compartment. If this is not possible some form of portable bilge suction should be set up. Drainage from the compartment on fire should be established downward to the bilge or lowest point in the section of the ship being dealt with. Keep in mind that two 11/2-inch fire hoses under 100 psi will discharge one ton of water per minute into the ship. If this rate of flow is allowed to go on long enough without attention, the ship will either capsize or sink.
Once you arrive on scene to fight the fire you should cool down the door entrance to the compartment or zone on fire. Once the entrance is cool, a backup man can step forward and, while standing outside the swing of the door, crack open the door and slip the 4-foot applicator into the opened door to continue cooling the back side of the door, It is important to stand outside the swing of the door due to the possibility of the door being blown open when fresh air enters into the compartment through the crack in the door.
Open the door fully while using a vertical sweeping motion with the attack nozzle on high velocity fog. This water action will keep the smoke and fire gases inside the compartment.
At this point the emergency squad officer can make a determination as to what type of attack should be made. If the compartment is small then an indirect attack can be mounted from the compartment entrance. Types of indirect attack are as follows:
1. Point attack nozzle into overhead and alternate between solid stream and high velocity fog for about 30 seconds; then close the compartment door. The water flashes to steam and smothers the compartment.
2. If the seat of the fire can be seen from the door, the nozzle man can use solid stream to hit the fire from the door without ever entering the compartment. This has the advantage of keeping the fire fighters out of the hot gases and smoke in the compartment.
If the compartment is very large then a direct attack must be mounted; the procedure is for the hose men to enter the compartment while staying low to the deck. Do not spray water into the overhead or attempt to cool down bulkheads while making the approach to the seat of the fire. To do this will cause steam to be generated and cause the thermal boundary to be brought to the deck level, making it impossible for the fire fighters to stay in the compartment. It might be best to keep the attack nozzle shut off during the approach if this is possible. Use only the backup nozzle and applicator for a heat shield and cooling. Once within range of the seat of the fire, apply water vigorously at the seat of the fire until the fire is extinguished. Use only the amount of water necessary to do the job. Remember, you are fighting a fire in a ship and any water you put into the ship must be taken out.
At this point the officer in charge should arrange for bilge suction to be started on the compartment. If this is not possible some form of portable bilge suction should be set up. Drainage from the compartment on fire should be established downward to the bilge or lowest point in the section of the ship being dealt with. Keep in mind that two 11/2-inch fire hoses under 100 psi will discharge one ton of water per minute into the ship. If this rate of flow is allowed to go on long enough without attention, the ship will either capsize or sink.
Labels:
DAMAGE CONTROL
FIRE FIGHTING ABOARD SHIP #3 (EMERGENCY LOCKER)
EMERGENCY LOCKER
As crew members arrive at the Emergency Locker, they should start getting prepared with their assigned equipment. This should be automatic and the crew members should not have to be told to do so. The following should be done:
1. Breathing apparatus men don their protective clothing immediately. The protective clothing provided in the locker is called a fireman's outfit. U.S. Coast Guard regulations do not specify exactly what a fireman's outfit is, but it is understood that it is the clothing that a fireman would wear to protect himself from the radiant heat of the fire and the hot gases of the fire. This clothing will include a foul weather gear top and bottom, rubber boots, and rubber gloves.
2. Breathing apparatus men now don their breathing apparatus and place it in the standby mode.
a. For the tank type breathing apparatus such as the Scott Air-Pak, this means the tank strapped on with tank valve open, the regulator set up, and the face mask hung off from the neck or tucked under one shoulder strap. The breathing hose is not yet plugged in.
3. Assigned equipment in the locker is picked up and checked out.
4. The fire fighters leave for the location of the fire.
Emergency Crew at the Scene
When the emergency crew arrives at the scene the officer in charge of the squad will take over from the witness as scene leader. The officer should obtain an update from the witness on the conditions at the scene. This information should include:
1. Whether boundaries have been set and if so then where.
2. Whether boundaries are holding and if not then where the fire is spreading.
3. What closures have been made and ventilation secured.
The officer in charge is now in a position to make a decision on how to fight the fire. He should direct the emergency squad to set up at least two hoses and lead them to the entrance to the area or zone on fire. It is preferable that the setup and the fire station selected be on the weather deck. Usually the interior of the ship is smoked out or about to be smoked out and visibility and breathing conditions are deteriorating rapidly. Interior fire stations should be used only as a last resort and then the farthest interior fire station from the fire should be selected.
It is preferable that the two fire hoses being run out should be led from separate fire stations but where this is not possible then they should be led from a single fire station using a Y-gate. Sufficient lengths of fire hose must be laid out to reach the farthest spot in the fire area to be entered. The number of lengths needed will have been previously determined during mock attack on the area in your weekly fire drills.
One fire hose should be fitted with an all-purpose nozzle and will be used as the attack nozzle. The other hose will be fitted with an all-purpose nozzle and 4-foot applicator and will be used as a backup hose during approach. The fine fog mist from the applicator will provide a heat shield for the fire fighters and also act to cool them during approach.
Each hose must be manned by a nozzle man and backup man. Both men on each hose must be fully dressed out and must be wearing breathing apparatus. These men need not be wearing safety lines since their hoses will be used to find their way out if necessary or can be used for rescuers to find their way in to the fire fighters.
As crew members arrive at the Emergency Locker, they should start getting prepared with their assigned equipment. This should be automatic and the crew members should not have to be told to do so. The following should be done:
1. Breathing apparatus men don their protective clothing immediately. The protective clothing provided in the locker is called a fireman's outfit. U.S. Coast Guard regulations do not specify exactly what a fireman's outfit is, but it is understood that it is the clothing that a fireman would wear to protect himself from the radiant heat of the fire and the hot gases of the fire. This clothing will include a foul weather gear top and bottom, rubber boots, and rubber gloves.
2. Breathing apparatus men now don their breathing apparatus and place it in the standby mode.
a. For the tank type breathing apparatus such as the Scott Air-Pak, this means the tank strapped on with tank valve open, the regulator set up, and the face mask hung off from the neck or tucked under one shoulder strap. The breathing hose is not yet plugged in.
3. Assigned equipment in the locker is picked up and checked out.
4. The fire fighters leave for the location of the fire.
Emergency Crew at the Scene
When the emergency crew arrives at the scene the officer in charge of the squad will take over from the witness as scene leader. The officer should obtain an update from the witness on the conditions at the scene. This information should include:
1. Whether boundaries have been set and if so then where.
2. Whether boundaries are holding and if not then where the fire is spreading.
3. What closures have been made and ventilation secured.
The officer in charge is now in a position to make a decision on how to fight the fire. He should direct the emergency squad to set up at least two hoses and lead them to the entrance to the area or zone on fire. It is preferable that the setup and the fire station selected be on the weather deck. Usually the interior of the ship is smoked out or about to be smoked out and visibility and breathing conditions are deteriorating rapidly. Interior fire stations should be used only as a last resort and then the farthest interior fire station from the fire should be selected.
It is preferable that the two fire hoses being run out should be led from separate fire stations but where this is not possible then they should be led from a single fire station using a Y-gate. Sufficient lengths of fire hose must be laid out to reach the farthest spot in the fire area to be entered. The number of lengths needed will have been previously determined during mock attack on the area in your weekly fire drills.
One fire hose should be fitted with an all-purpose nozzle and will be used as the attack nozzle. The other hose will be fitted with an all-purpose nozzle and 4-foot applicator and will be used as a backup hose during approach. The fine fog mist from the applicator will provide a heat shield for the fire fighters and also act to cool them during approach.
Each hose must be manned by a nozzle man and backup man. Both men on each hose must be fully dressed out and must be wearing breathing apparatus. These men need not be wearing safety lines since their hoses will be used to find their way out if necessary or can be used for rescuers to find their way in to the fire fighters.
Labels:
DAMAGE CONTROL
FIRE FIGHTING ABOARD SHIP #2 (PREPAREING)
STEPS TO FIGHTING FIRES ABOARD SHIP:
The crew member discovering the fire should take the following action:
1. Before leaving the scene, if you can close the door, cover, or damper through which the fire was discovered. If a vent switch is handy shut it off but do not waste time looking for it if you do not know where it is.
2. Notify the bridge of the fire. If there is a sound powered phone or dial phone handy, use it. Otherwise, run to the bridge or the engine room, whichever is closest, and notify them of the fire. Keep in mind that the engine room has a sound powered phone to the bridge as well as a general alarm actuator. Pass the following information:
a. Location of fire-by compartment number if possible or by verbal description or use of the compartment.
b. Type of fire-class of the fire if known.
3. Return to the scene of the fire after passing the word. Keep in mind that the witness knows more about the fire at that moment than any other crew member on the ship. The witness should take charge at the scene until an officer arrives to take over.
1. Keep the fire from spreading. In the case of a major fire it is important to keep the fire from spreading even if the fire cannot be fought directly. Later as more crew members arrive on the scene an attack can begin. Set boundaries around the fire area:
a. Break out the fire hoses around the area and begin cooling down the boundary bulkheads, the deck area that is the overhead for the compartment on fire, and the overhead of the compartment below, which is the deck of the compartment on fire. Even if the fire cannot be fought directly later on, the fire will not spread once boundaries have been set.
b. Clear flammables away from the boundary bulkheads. Remember that the steel bulkheads surrounding the compartment on fire will get red hot as the fire burns on and any nearby combustible may be in danger of igniting. The combustibles need only be moved away from the bulkheads. Later as more crew members show up these combustibles can be moved farther away.
c. Continue making closures and shutting off ventilation. Locate all vent switches and shut them down. Close covers to vent openings, close portholes, skylights, and any additional rear doors that may still be open.
On the Bridge
Once the word has been received on the bridge, take the following action:
1. Ring the general alarm bell with the signal for Fire and Emergency and at the same time give this signal on the ship's whistle. The signal for Fire and Emergency is the continuous ringing of the ship's general alarm bell for at least 10 seconds supplemented by the same signal on the ship's whistle.
2. Shut down the ventilation for the area involved using the master shut-down switches on the bridge. have a master shut-off switch located on the bridge. This includes vent systems for the berthing spaces, engine room, and the cargo spaces.
3. Start taking notes on what is happening. Jot down the time, the name of the witness if known, the location of the fire, and the type of fire. On the navigation work sheet mark off the ship's position at the time of occurrence. Note this position in the notes. The master will want all of this information when he gets on the bridge.
The crew member discovering the fire should take the following action:
1. Before leaving the scene, if you can close the door, cover, or damper through which the fire was discovered. If a vent switch is handy shut it off but do not waste time looking for it if you do not know where it is.
2. Notify the bridge of the fire. If there is a sound powered phone or dial phone handy, use it. Otherwise, run to the bridge or the engine room, whichever is closest, and notify them of the fire. Keep in mind that the engine room has a sound powered phone to the bridge as well as a general alarm actuator. Pass the following information:
a. Location of fire-by compartment number if possible or by verbal description or use of the compartment.
b. Type of fire-class of the fire if known.
3. Return to the scene of the fire after passing the word. Keep in mind that the witness knows more about the fire at that moment than any other crew member on the ship. The witness should take charge at the scene until an officer arrives to take over.
1. Keep the fire from spreading. In the case of a major fire it is important to keep the fire from spreading even if the fire cannot be fought directly. Later as more crew members arrive on the scene an attack can begin. Set boundaries around the fire area:
a. Break out the fire hoses around the area and begin cooling down the boundary bulkheads, the deck area that is the overhead for the compartment on fire, and the overhead of the compartment below, which is the deck of the compartment on fire. Even if the fire cannot be fought directly later on, the fire will not spread once boundaries have been set.
b. Clear flammables away from the boundary bulkheads. Remember that the steel bulkheads surrounding the compartment on fire will get red hot as the fire burns on and any nearby combustible may be in danger of igniting. The combustibles need only be moved away from the bulkheads. Later as more crew members show up these combustibles can be moved farther away.
c. Continue making closures and shutting off ventilation. Locate all vent switches and shut them down. Close covers to vent openings, close portholes, skylights, and any additional rear doors that may still be open.
On the Bridge
Once the word has been received on the bridge, take the following action:
1. Ring the general alarm bell with the signal for Fire and Emergency and at the same time give this signal on the ship's whistle. The signal for Fire and Emergency is the continuous ringing of the ship's general alarm bell for at least 10 seconds supplemented by the same signal on the ship's whistle.
2. Shut down the ventilation for the area involved using the master shut-down switches on the bridge. have a master shut-off switch located on the bridge. This includes vent systems for the berthing spaces, engine room, and the cargo spaces.
3. Start taking notes on what is happening. Jot down the time, the name of the witness if known, the location of the fire, and the type of fire. On the navigation work sheet mark off the ship's position at the time of occurrence. Note this position in the notes. The master will want all of this information when he gets on the bridge.
Labels:
DAMAGE CONTROL
FIRE FIGHTING ABOARD SHIP #1 (CLASS OF FIRES)
Fires can be classified into four groups:
Class A-Fires in ordinary combustible materials such as mattresses, dunnage, wood, canvas, etc. These fires are best extinguished by the cooling effects of water or water fog.
Class B-Fires in such as gasoline, oil, lubricating oil, diesel oil, tar, greases, etc. The blanketing or smothering effect of the extinguishing agent is important.
Class C-Fires in live electrical equipment, such as switchboard insulation, transformer terminals, etc. The extinguishing agents must be nonconducting so that electrical shock is not experienced by the firefighter.
Class D-Fires in combustible metals like magnesium, sodium, titanium, lithium, etc.
Except for a fire caused by a catastrophic event, a fire starts out small.
If it is discovered, it can probably be extinguished by one of the portable extinguishers.
Different types of fires require different types of extinguishers. Portable extinguishers are placed aboard ship according to the type of hazard that might be seen in the space where they are located. Portable extinguishers are first aid measures only and are not intended as a substitute for hose lines when the fire is beyond the limitations of the extinguisher in use. Here are the types of fires for which each portable extinguisher can be used:
1. Water (stored pressure type). Use on class A fires. Do not use on electrical fires.
How to operate: Break the seal and pull the locking pin. Direct the nozzle at the base of the fire. Grip the lever and squeeze.
Maintenance: Inspect monthly for full pressure and physical condition. Discharge and refill with fresh water annually.
2. Foam (stored pressure type). Use on class Aand class B fires. Do not use on electrical fires.
How to operate: Break the seal and pull the locking pin. Direct the nozzle at the base of the fire. Grip the lever and squeeze.
Maintenance: Inspect monthly for full pressure and physical condition. Annually discharge and refill with fresh foam solution or replace the foam hose cartridge (depending on design).
3. Carbon dioxide. Use on class B and class C fires. C02 extinguishers are not permitted in passenger and crew quarters.
How to operate: Break the seal and pull the locking pin. Hold the nozzle on the insulated handle, squeeze the lever, and direct the gas at the base ofthe fire.
Maintenance: Inspect monthly for condition of seal and bottle. Weigh the bottle annually. If the net weight without the hose and horn is down by 10 percent of the full charge then the bottle requires recharging. Re-hydro the bottle every 12 years if the bottle did not require recharging during that interval.
4. Halon 1211. Use on class B and class C fires. Some of the larger capacity Halon bottles may have an A rating. Check the face of the bottle for specifics.
How to operate: Break the seal and pull the locking pin. Direct the nozzle at the base of the fire. Grip the lever and squeeze.
Maintenance: Inspect monthly for full pressure gauge reading and physical condition. Check the pressure gauge and weigh the bottle annually. Rehydro at intervals required by the D.O.T. Interval will depend on the standards to which the bottle was built. Both Halon 1211 and 1301 may be used in portable extinguishers.
5. Dry chemical. The class of fire for which the extinguisher is effective will depend on the dry chemical in it. Check the face of the bottle for specifics.
Sodium bicarbonate and potassium bicarbonate: Use on class B and class C fires.
Mono-ammonium phosphate: Use on class A, class B, and class C fires. How to operate: Depends on the design of the extinguisher.
External cartridge dry chemical type: Pull the hose up sharply to break the seal. Press the activation plunger. Squeeze the lever on the discharge hose to confirm the powder flow before committing to the fire. Discharge the powder at the base of the fire.
Stored pressure type: Break the seal and pull the locking pin. Direct the hose at the base ofthe fire and squeeze the lever.
Maintenance: Inspect monthly for full pressure gauge on stored pressure extinguisher. Inspect all types for condition of hose and container.
6. Dry powder. The term dry powder has been reserved exclusively by the National Fire Protection Association (NFPA) to describe powdered agents which are intended for use on class D fires. The extinguishing agent must be matched to the class D material of concern. There is no powder that is effective against all of the 26 class D metals. Fire extinguishers are now provided with symbols that are displayed on the bottle to show which type of fire the extinguisher is effective against: A, B, C, or D.
1. Soda acid. Use on class A fires. Do not use on electrical fires.
How to operate: Turn upside down. Direct nozzle at base offire. Recharge. Maintenance: Inspect monthly for condition. Annually discharge and refill.
2. Foam. Use on class A and class B fires. Do not use on electrical fires.
How to operate: Turn upside down. Direct nozzle at base of fire. Recharge. Maintenance: Inspect monthly for condition. Discharge and refill annually.
Class A-Fires in ordinary combustible materials such as mattresses, dunnage, wood, canvas, etc. These fires are best extinguished by the cooling effects of water or water fog.
Class B-Fires in such as gasoline, oil, lubricating oil, diesel oil, tar, greases, etc. The blanketing or smothering effect of the extinguishing agent is important.
Class C-Fires in live electrical equipment, such as switchboard insulation, transformer terminals, etc. The extinguishing agents must be nonconducting so that electrical shock is not experienced by the firefighter.
Class D-Fires in combustible metals like magnesium, sodium, titanium, lithium, etc.
Except for a fire caused by a catastrophic event, a fire starts out small.
If it is discovered, it can probably be extinguished by one of the portable extinguishers.
Different types of fires require different types of extinguishers. Portable extinguishers are placed aboard ship according to the type of hazard that might be seen in the space where they are located. Portable extinguishers are first aid measures only and are not intended as a substitute for hose lines when the fire is beyond the limitations of the extinguisher in use. Here are the types of fires for which each portable extinguisher can be used:
1. Water (stored pressure type). Use on class A fires. Do not use on electrical fires.
How to operate: Break the seal and pull the locking pin. Direct the nozzle at the base of the fire. Grip the lever and squeeze.
Maintenance: Inspect monthly for full pressure and physical condition. Discharge and refill with fresh water annually.
2. Foam (stored pressure type). Use on class Aand class B fires. Do not use on electrical fires.
How to operate: Break the seal and pull the locking pin. Direct the nozzle at the base of the fire. Grip the lever and squeeze.
Maintenance: Inspect monthly for full pressure and physical condition. Annually discharge and refill with fresh foam solution or replace the foam hose cartridge (depending on design).
3. Carbon dioxide. Use on class B and class C fires. C02 extinguishers are not permitted in passenger and crew quarters.
How to operate: Break the seal and pull the locking pin. Hold the nozzle on the insulated handle, squeeze the lever, and direct the gas at the base ofthe fire.
Maintenance: Inspect monthly for condition of seal and bottle. Weigh the bottle annually. If the net weight without the hose and horn is down by 10 percent of the full charge then the bottle requires recharging. Re-hydro the bottle every 12 years if the bottle did not require recharging during that interval.
4. Halon 1211. Use on class B and class C fires. Some of the larger capacity Halon bottles may have an A rating. Check the face of the bottle for specifics.
How to operate: Break the seal and pull the locking pin. Direct the nozzle at the base of the fire. Grip the lever and squeeze.
Maintenance: Inspect monthly for full pressure gauge reading and physical condition. Check the pressure gauge and weigh the bottle annually. Rehydro at intervals required by the D.O.T. Interval will depend on the standards to which the bottle was built. Both Halon 1211 and 1301 may be used in portable extinguishers.
5. Dry chemical. The class of fire for which the extinguisher is effective will depend on the dry chemical in it. Check the face of the bottle for specifics.
Sodium bicarbonate and potassium bicarbonate: Use on class B and class C fires.
Mono-ammonium phosphate: Use on class A, class B, and class C fires. How to operate: Depends on the design of the extinguisher.
External cartridge dry chemical type: Pull the hose up sharply to break the seal. Press the activation plunger. Squeeze the lever on the discharge hose to confirm the powder flow before committing to the fire. Discharge the powder at the base of the fire.
Stored pressure type: Break the seal and pull the locking pin. Direct the hose at the base ofthe fire and squeeze the lever.
Maintenance: Inspect monthly for full pressure gauge on stored pressure extinguisher. Inspect all types for condition of hose and container.
6. Dry powder. The term dry powder has been reserved exclusively by the National Fire Protection Association (NFPA) to describe powdered agents which are intended for use on class D fires. The extinguishing agent must be matched to the class D material of concern. There is no powder that is effective against all of the 26 class D metals. Fire extinguishers are now provided with symbols that are displayed on the bottle to show which type of fire the extinguisher is effective against: A, B, C, or D.
1. Soda acid. Use on class A fires. Do not use on electrical fires.
How to operate: Turn upside down. Direct nozzle at base offire. Recharge. Maintenance: Inspect monthly for condition. Annually discharge and refill.
2. Foam. Use on class A and class B fires. Do not use on electrical fires.
How to operate: Turn upside down. Direct nozzle at base of fire. Recharge. Maintenance: Inspect monthly for condition. Discharge and refill annually.